Wireless Load Cell Connection Module DLV

DLV-T - DLV-R Wireless Communication Boxes
DLV-T - DLV-R Wireless Communication Boxes

Wireless Bluetooth load cell connection module, for wireless communication of weighing data from load cells to weighing indicator.

See further under Product Information.

in stock
Please contact us for the current delivery time.
Request quotation
Prices exlude vat
  1. Type: DLV Description: Wireless Bluetooth load cell connection module (kit of receiver + transmitter) Item code: 19080101 Price € 680.00
  2. Type: DLV-R Description: Wireless Bluetooth load cell connection receiver Item code: 19080102 Price € 385.00
  3. Type: DLV-T Description: Wireless Bluetooth load cell connection transmitter Item code: 19080103 Price € 295.00

Wireless Bluetooth load cell connection kit DLV

Properties

  • transmission system: Bluetooth 4.0 Low Energy 2.4 GHz
  • processor: ARM Cortex M0
  • distance range: 20-30 meters

Receiver

Parameter Value
Receiver Connected to the weighing indicator as a load cell
Power supply voltage from the weighing indicator 5-10 Vdc
Power consumption max. 25mA
Constant emulated load cell 2.0 mV/V
Emulated voltage Proportional to the voltage supplied by the weighing indicator
D / A converter 16-bit, effective resolution 16-bit
Zero drift of amplifiers <5ppm/K
Resistors in the analog circuit 0.1%, 25ppm/K
Total error after calibration (estimated): max. 90ppm/K (0.009%/K)
Operating temperature -40˚C up to +85˚C
Number of transmitter connected to one receiver 1-4
Number of channels 1-128

Transmitter

Parameter Value
Excitation 3.3 Vdc max 100mA
D / A converter 16-bit, effective resolution 16-bit
Frequency of measurement 4.17x/sek (max. 50x/sek)
Resistors in the analog circuit 0.1%, 25ppm/K
Total error after calibration (estimated) max. 75ppm/K (0.0075%/K)
Power Li-Ion / Li-Po 3.7V battery
Power consumption without load cell < 5mA
Power consumption by a 360Ω load cell 9.2 mA
Power consumption in sleep mode < 0.3mA
Operating time (without sleep mode) 24h for a 400mAh battery
Operating time (without battery) -40˚C up to +85˚C

Scale types: ,